{"product_id":"special-scale-meter-nsn-6625-01-012-6560-p-n-3675008-026","title":"NOS Northrop Grumman Systems Corp Special Scale Meter NSN:6625-01-012-6560 P\/N:3675008-026 Model:9-2150-107","description":"\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-12 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"pull-left\"\u003e\n\u003ch1 class=\"font2em\"\u003eSpecial Scale Meter\u003c\/h1\u003e\n\u003cspan class=\"block\"\u003eNSN:6625-01-012-6560  P\/N:3675008-026 Model:9-2150-107\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pull-right\"\u003e\u003cimg src=\"https:\/\/nationalstocknumber.info\/public\/images\/xitar.png.pagespeed.ic.fKDy9An-gD.webp\" title=\"ITAR Registered company\" alt=\"ITAR Registered seal\" data-pagespeed-url-hash=\"484704097\" onload=\"pagespeed.CriticalImages.checkImageForCriticality(this);\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-6 col-md-12 col-sm-12 margin-top\"\u003e\n\u003ch5 class=\"bold font12em\"\u003eSchedule B \u0026amp; Trade:\u003c\/h5\u003e\n\u003cul class=\"list-plain list-padding\"\u003e\n\u003cli\u003eSchedule B:\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"theme-color\"\u003e9030908030\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(NAICS 334515)\u003cbr\u003e\n\u003cp\u003eParts and accessories of articles of schedule b subheading 9030.39\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eSITC:\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"theme-color\"\u003e87479\u003c\/span\u003e\u003cbr\u003e\n\u003cp\u003eParts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quantities and devices measuring etc. Ionized radiations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnd Use:\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"theme-color\"\u003e21160\u003c\/span\u003e\u003cbr\u003e\n\u003cp\u003eMeasuring, testing, control instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-8 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"panel panel-3d\"\u003e\n\u003cdiv class=\"panel-heading\"\u003eNSN Properties and Flags\u003c\/div\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eNATO Stock Number\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e6625-01-012-6560\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDEMIL\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eYes - ITAR Controlled\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCircuit Current For Which Designed\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eDc\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDielectric Withstanding Voltage In Volts\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1500.0\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eOverall Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e7.730 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Mounting Facilities Parallel To Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 6.043 inches and 6.057 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Mounting Facilities Parallel To Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 0.718 inches and 0.732 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eOverall Height\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1.530 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eOverall Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e6.700 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Hole Diameter\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.190 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eScale Division Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e30 single indicator single range\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eEnvironmental Protection\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eHumidity resistant and shock resistant and vibration resistant\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFurnished Items And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eNut 8; washer 16\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eIndicator Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eDial w\/pointer\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInstallation Design\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003ePanel\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Arrangement Style\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eFour hole\/stud rectangular\/square\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSensitivity Rating\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e20.0 milliamperes\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDial Scale Marking Color\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBlack single indicator single range\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eAccuracy In Percent\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e-2.0\/+2.0 at full scale single indicator single range\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eUnable To Decode\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eUnable to decode or unable to decode\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMeter Depth Behind Mounting Flange\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5.770 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMeter Body Width Behind Mounting Flange\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5.450 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMovement Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMoving coil, permanent magnet\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBackground Color\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eWhite single indicator single range\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003ePointer Color\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBlack single indicator single range\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eScale Marking\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003ePsig 0; 10; 20; 30\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Facility Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e4 screw and 4 unthreaded hole\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eScale Graduation Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eLinear single indicator single range\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMeter Body Height Behind Mounting Flange\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1.225 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFeatures Provided\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eElectrical overload protection and luminous scale marking and non glare glass and self-illumination facility and zero adjuster\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMovement Suspension Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eJewel pivot base\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCircuit Attachment Method And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2 threaded stud\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eOperating Voltage Rating In Volts\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e28.0 dc\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSpecial Features\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eEdgewise mtg; ruggedest\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMaterial\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eSteel\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eNuclear Hardness Critical Feature\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eNonhardened\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSurface Treatment\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003ePaint\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSpecial Test Features\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eDrawing iaw MIL-STD-100A; vibration iaw MIL-STD-167; shock iaw MIL-S-901; marking iaw MIL-STD-130; sealing iaw MIL-STD-108D\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eStyle Designator\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eRectangular semi-flush mtg\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSupplementary Features\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eDamping factor 2.5 max; response time 2 sec max; insulation res 20 megohms min\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFsc Application Data\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTest set, elect. Equip.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Northrop Grumman Systems Corp","offers":[{"title":"Default Title","offer_id":35697004230,"sku":"WH3158 R10 2ND LEVEL","price":359.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/4967\/products\/IMG_0499.jpg?v=1586196678","url":"https:\/\/ctssurplusandsupply.com\/products\/special-scale-meter-nsn-6625-01-012-6560-p-n-3675008-026","provider":"CTS Surplus and Supply","version":"1.0","type":"link"}