{"product_id":"power-transformer-nsn-5950-00-127-7043-p-n-401090","title":"Target Corporation Power Transformer NSN:5950-00-127-7043 Model:401090","description":"\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-12 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"pull-left\"\u003e\n\u003ch1 class=\"font2em\"\u003ePower Transformer\u003c\/h1\u003e\n\u003cspan class=\"block\"\u003eNSN:5950-00-127-7043  Model:401090\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pull-right\"\u003e\u003cimg src=\"https:\/\/nationalstocknumber.info\/public\/images\/xitar.png.pagespeed.ic.fKDy9An-gD.webp\" title=\"ITAR Registered company\" alt=\"ITAR Registered seal\" data-pagespeed-url-hash=\"484704097\" onload=\"pagespeed.CriticalImages.checkImageForCriticality(this);\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-6 col-md-12 col-sm-12 margin-top\"\u003e\n\u003cp\u003eA transformer consisting of one or more primary win din (s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1) , pulse.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-8 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"panel panel-3d\"\u003e\n\u003cdiv class=\"panel-heading\"\u003eNSN Properties and Flags\u003c\/div\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eNATO Stock Number\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5950-00-127-7043\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDEMIL\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eYes - ITAR Controlled\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eReliability Indicator\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eNot established\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Mounting Facilities Parallel To Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2.125 inches single mounting facility single center group\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Mounting Facilities Parallel To Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1.750 inches single mounting facility single center group\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFrequency Rating\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e400.0 hertz single component\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInput-output Phase Relationship\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eThree phase to three phase single component\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTransformer Winding Connection Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eDelta-wye\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eWinding Shielding Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eInternal shield grounded to in closure single component\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2.750 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2.380 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Height\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1.750 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMaximum Operating Temp\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e85.0 degrees celsius\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInclosure Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eFully enclosed\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Facility Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e4 single group\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eThreaded stud single group\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eWinding Function And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1 primary single component and 5 secondary single component\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThread Size\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.138 inches single group\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eWinding Operating Current\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e750.0 milliamperes dc single component 2ND secondary\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eWinding Operating Voltage\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5.00 dc volts single component 3RD secondary\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSpecial Features\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1PRIMARY winding; 5SECONDARY win dings secondary voltage and current have been rectified\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThread Series Designator\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eUnc single group\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTerminal Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e17 solder stud\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Target Corporation","offers":[{"title":"Default Title","offer_id":42792343366,"sku":"3156 R9 2ND LEVEL","price":519.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/4967\/products\/IMG_0197.jpg?v=1585767719","url":"https:\/\/ctssurplusandsupply.com\/products\/power-transformer-nsn-5950-00-127-7043-p-n-401090","provider":"CTS Surplus and Supply","version":"1.0","type":"link"}