{"product_id":"heinemann-am2-z159-6-circuit-breaker-25a-65v-nsn-5925-01-146-5527","title":"Heinemann AM2-Z159-6 Circuit Breaker 25A 65V NSN:5925-01-146-5527","description":"\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-12 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"pull-left\"\u003e\n\u003ch1 class=\"font2em\"\u003eCircuit Breaker\u003c\/h1\u003e\n\u003cspan class=\"block\"\u003eNSN:5925-01-146-5527    P\/N:AM2-Z159-6    Model:SM-A-838525-4\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pull-right\"\u003e\u003cimg src=\"https:\/\/nationalstocknumber.info\/public\/images\/itar.png\" title=\"ITAR Registered company\" alt=\"ITAR Registered seal\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-6 col-md-12 col-sm-12 margin-top\"\u003e\n\u003cp\u003eA device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto \"breaker\" assemblies. See also switch (as modified) ; and controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-8 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"panel panel-3d\"\u003e\n\u003cdiv class=\"panel-heading\"\u003eNSN Properties and Flags\u003c\/div\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eNATO Stock Number\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5925-01-146-5527\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDEMIL\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eYes - ITAR Controlled\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Style\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMultipole-multiple actuator type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 2.480 inches and 2.520 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 1.480 inches and 1.520 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCase Material\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003ePlastic\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Terminals Parallel To Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 1.928 inches and 1.948 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Terminals Parallel To Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 0.740 inches and 0.760 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDistance Between Centerlines Of Mounting Facilities Parallel To Body Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 2.052 inches and 2.072 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDistance Between Centerlines Of Mounting Facilities Parallel To Body Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 0.740 inches and 0.760 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFragility Factor\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eModerately rugged\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBoss Height\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eBetween 0.130 inches and 0.150 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Surface To Terminal End Distance\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e3.590 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003ePole Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eArc Quenching Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMagnetic blowout\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Facility Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e4 threaded hole\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eStorage Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eGeneral purpose warehouse\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSpecial Handling Feature\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMagnetic\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFeatures Provided\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eHigh inrush protection\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThready Qty Per Inch (tpi)\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e32\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMaximum Continuous Load Current Rating Per Pole\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e25.0 amperes dc all locations\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eOperating Voltage Type And Rating Per Pole In Volts\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e65.0 dc first location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1000.0 dc first location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCircuit Protection Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eOvercurrent all locations\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTrip Release Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMagnetic-hydraulic all locations\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTrip Release Characteristic\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTime delay first location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e125.0 all locations\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eReset Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eManual\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMain Contact Tripping Mechanism Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTrip free\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eManual Actuator Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2 toggle\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eActuator Function\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTrip-reset\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eActuator Position Designation\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eAt each pole\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eExternal Actuator Linkage Arrangement\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eOne and two linked\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInternal Trip Release Configuration\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eSeries trip all locations\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThread Size\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.138 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTrip Delay Time In Seconds Per Rated Continuous Current\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e3.000 at 200 pct all locations and 11.000 at 200 pct all locations\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInclosure Protection Type For Which Designed\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMoisture resistant and fungus resistant\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCriticality Code Justification\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eFeat\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSpecial Features\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eHigh inrush pole one only\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eUnpackaged Unit Weight\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e6.438 pounds\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTest Data Document\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e80063-sm-a-838525 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThread Series Designator\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eUnc\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTerminal Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e4 threaded stud\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Heinemann","offers":[{"title":"Default Title","offer_id":32138922197086,"sku":"3158 R1 2ND (MISC)","price":45.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/4967\/products\/IMG_3309_ec954c4c-66b3-4138-a5c5-664afbff23dc.jpg?v=1597954136","url":"https:\/\/ctssurplusandsupply.com\/products\/heinemann-am2-z159-6-circuit-breaker-25a-65v-nsn-5925-01-146-5527","provider":"CTS Surplus and Supply","version":"1.0","type":"link"}