{"product_id":"circuit-breaker-nsn-5925-01-276-0456-p-n-cd1-z290-2","title":"Heinemann CD1-Z290-2 Circuit Breaker 50A 120V 50\/60HZ NSN: 5925-01-276-0456","description":"\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-12 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"pull-left\"\u003e\n\u003ch1 class=\"font2em\"\u003eCircuit Breaker\u003c\/h1\u003e\n\u003cspan class=\"block\"\u003eNSN: 5925-01-276-0456   P\/N: CD1-Z290-2   Model: WSS96340-1\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pull-right\"\u003e\u003cimg src=\"https:\/\/nationalstocknumber.info\/public\/images\/itar.png\" title=\"ITAR Registered company\" alt=\"ITAR Registered seal\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-6 col-md-12 col-sm-12 margin-top\"\u003e\n\u003cp\u003eA device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto \"breaker\" assemblies. See also switch (as modified) ; and controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"row margin-top-more\"\u003e\n\u003cdiv class=\"col-lg-8 col-md-12 col-sm-12\"\u003e\n\u003cdiv class=\"panel panel-3d\"\u003e\n\u003cdiv class=\"panel-heading\"\u003eNSN Properties and Flags\u003c\/div\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eNATO Stock Number\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5925-01-276-0456\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDEMIL\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eYes - ITAR Controlled\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Style\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eSingle pole type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Slot Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.164 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5.800 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBody Width\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1.025 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCase Material\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003ePlastic\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCenter To Center Distance Between Terminals Parallel To Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e3.547 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eDistance Between Centerlines Of Mounting Facilities Parallel To Body Length\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e4.750 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFragility Factor\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eModerately rugged\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eBoss Height\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.220 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Surface To Terminal End Distance\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2.610 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003ePole Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eArc Quenching Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMagnetic blowout\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMounting Facility Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2 threaded hole and 1 slot\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eStorage Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eGeneral purpose warehouse\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eSpecial Handling Feature\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMagnetic\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThready Qty Per Inch (tpi)\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e32\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMaximum Continuous Load Current Rating Per Pole\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e50.0 amperes ac single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eOperating Voltage Type And Rating Per Pole In Volts\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e120.0 ac single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e5000.0 ac single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eCircuit Protection Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eOvercurrent single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTrip Release Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eMagnetic-hydraulic single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTrip Release Characteristic\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTime delay single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e125.0 single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eReset Method\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eManual\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eMain Contact Tripping Mechanism Type\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTrip free\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eManual Actuator Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e1 toggle\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eActuator Function\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eTrip-reset\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eActuator Position Designation\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eAt pole one\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInternal Trip Release Configuration\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eSeries trip single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThread Size\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.138 inches\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTrip Delay Time In Seconds Per Rated Continuous Current\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2.000 at 200 pct single location and 10.000 at 200 pct single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eInclosure Protection Type For Which Designed\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eFungus resistant and moisture resistant\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eFrequency In Hertz\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e60.0 single location\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eUnpackaged Unit Weight\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e0.562 pounds\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eThread Series Designator\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003eUnc\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width bold padding-top\"\u003eTerminal Type And Quantity\u003c\/div\u003e\n\u003cdiv class=\"pull-left full-width\"\u003e2 threaded stud\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Heinemann","offers":[{"title":"Default Title","offer_id":42261406470,"sku":"WH3158 R1 2ND LEVEL","price":24.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/4967\/products\/IMG_0805.jpg?v=1591722217","url":"https:\/\/ctssurplusandsupply.com\/products\/circuit-breaker-nsn-5925-01-276-0456-p-n-cd1-z290-2","provider":"CTS Surplus and Supply","version":"1.0","type":"link"}